Avaliação da Capacidade Cardiorrespiratória (vo2máx) em Policiais Militares, com Testes Indiretos

 

http://portalrevistas.ucb.br/index.php/RBCM/index 

downloadpdf

Gerardo Rebelo Filho1, José A. Prada1, Glauber C. B. Silva2, José Cândido A. G. Neto2, Francisco N. Santos2, Raul A. Feitosa3 & Lucas Santos I. B. Alencar4

 

Resumo: O objetivo deste estudo foi avaliar o (VO2máx) de militares com testes indiretos de 1600m (ALMEIDA et al., 2010) e 12min (COOPER,1968). Participaram 49 militares masculinos, aptos fisicamente, média de idade de 25,6 ±3,10 anos, IMC 23 ±1,4 Kg.m2, selecionados aleatoriamente. O (VO2máx) foi mensurado através das equações de Cooper e Almeida após os testes; coletados e analisados os parâmetros fisiológicos: frequência cardíaca, glicemia e lactato pré e pós-testes e percepção subjetiva do esforço ao final. Observou-se grande fidedignidade entre eles, sendo o valor do (VO2máx) de 1600m (43,63±3,21) superior ao de 12min (39,42±4,18), mostrando aumento significativo (p<0,0001), atribuída à potência de exercício desenvolvida durante o teste, que pode ser observada nos valores de lactato no de 1600m. A prova de 1600m, mostrou-se como uma alternativa eficaz na mensuração do (VO2máx) em militares, portanto sendo uma medida indireta de baixo custo e fácil uso e de grande valia sua aplicabilidade nas Instituições Militares.

Palavras-chave: Consumo Máximo de Oxigênio; Teste de Aptidão Física (TAF); Parâmetros Fisiológicos; Exercício Físico Aeróbio

 

Abstract: The objective of this research was to evaluate the (VO2máx), in indirect tests of 1600m (Almeida et al., 2010) and 12 min (Cooper, 1968). 49 physically fit military aged 25.6±3.10 years, BMI 23±1.4 kg.m2, where randomly chosen according to the inclusion criteria of the research took part of it. The (VO2máx) was measured through COOPER and Almeida equations after the tests of 1600m and 12min run, collected and analyzed physiological parameters of cardiac frequency glycemia and lactate were collected before and after the tests. Besides, the subjective perception of effort at the end of each test was evaluated. Through the physiological parameters, it could be observed a great reliability between the 1600m and 12min run tests, in which the (vo2máx) value in the former (43.63±3.21) was higher than in the latter test (39.42±4.18), showing a significant incriase (p<0.0001), attributed to the power developed during the exercise test, which can be observed for lactate in the 1600m. The 1600m test, proved to be an effective alternative in measuring (vo2máx) in milytary, being an indirect measure of cost and ease of use and great value for their applicability in the military institutions.

Key words: Maximal Oxygen Consumption; Physical Fitness Test (TAF); Physiological Parameters; Aerobic Exercise.

 

1 Universidade Católica de Brasília-UCB- Taguatinga, DF
2 Universidade Estadual do Piauí, UESPI- Teresina, PI
3 Universidade Federal do Piauí
4 Faculdade Integral Diferencial